Pureline PureClO2 Electrochemical Chlorine Dioxide Generators HP Series Dioxide Pacific are the exclusive Australia & New Zealand Distributor for Pureline chlorine dioxide generators
|
|
Operation Pureline PureClO2 Electrochemical Chlorine Dioxide Generators HP Series
Revolutionary patented chlorine dioxide generators utilise one chemical Purecide E and electrical power to produce 99.5% pure chlorine dioxide. Chlorine dioxide is produced as a 1,000 – 5,000 ppm solution which is stored ready for accurate dosing with a metering pump.
|
|
|
|
Safety Chlorine dioxide has never been safer to produce and dose. Unlike other generator types which require storage of incompatible chemicals, the PureClO2 HP chlorine dioxide generator only requires one chemical Purecide E. The storage of incompatible chemicals (such as sodium chlorite and hydrochloric acid) represents an inherent safety risk, as the chemicals can possibly contact each other outside of the generator in case of spills. The PureClO2 HP generator has completely eliminated this risk.
Chlorine dioxide is produced in the PureClO2 HP generator as a gas. Chlorine dioxide gas is dissolved in water to form a pure 1,000 – 5,000 ppm solution. This concentration solution is safe to store and pump. Typical acid-chlorite generators produce 20,000 ppm solution in the reactor which can possibly explode if a vacuum is pulled on the reactor. In the case of high concentration acid-chlorite generators, if the dilution water fails, the concentration produced can cause spontaneous explosion without vacuum. The PureClO2 HP generator eliminates this safety risk.
Chlorine gas and hydrochloric acid are not required for the PureClO2 HP generator. Other generators require chlorine gas as a feed chemical. Chlorine gas has inherent safety risk due to its hazardous nature. Hydrochloric acid is a hazardous chemical which fumes and causes corrosion. The PureClO2 HP generator does not require these chemicals so the risk is eliminated.
|
|
High Efficiency Equals Lowest Running Cost The Pureline PureClO2 HP generator produces chlorine dioxide at extremely high efficiency and purity. Due to the excellent conversion capability, the maximum amount of sodium chlorite is converted to chlorine dioxide. As there are no other feed chemicals and the cost of electrical power is low, the PureClO2 HP generator running cost is very low. Sodium hydroxide is produced at 20% concentration as a by-product of the PureClO2 reaction process. In some cases, this is a useful chemical for cleaning or other pH correction applications. So, the cost of purchasing this chemical can be offset by the free provision of this chemical by the PureClO2 HP generator.
|
|
|
Corrosion Resistance The Pureline PureClO2 HP generator is completely pre-wired and plumbed into a polypropylene cabinet. All plumbing is schedule 80 grey uPVC and cPVC. Metering pump liquid ends are PVDF and elastomers are viton. The choice of chemically resistant materials ensures long equipment life.
|
|
Multiple Point Dosing from PLC and Touchscreen The Pureline PureClO2 HP generator is controlled from a central control panel which includes a Mitsubishi PLC and touchscreen. It is possible to control up to four separate dosing pumps from the dosing page using either flow proportional or residual control. PID setpoints can be entered so that accurate residual control is obtained. Incorporating control functionality into the control system eliminates the need for PID controllers. The touchscreen displays operation status of all items and alarms and can be equipped with ethernet for remote monitoring.
Most other two or three chemical chlorine dioxide generators require multiple generators for multiple dosing points. This can be expensive and require complex control systems. The Pureline PureClO2 HP generator can dose chlorine dioxide to many dosing points by the addition of one metering pump per dosing point. The only limitation is the capacity of the generator. The advantage is lower capital cost and greater flexibility to add dosing points at a later stage if processes require it.
|
|
|
|
Chemical Supply and Maintenance Dioxide Pacific offers the The Pureline PureClO2 HP generator as a complete package including Purecide E chemical supply and maintenance. We provide both breakdown and preventative maintenance to ensure reliable operation.
Purecide E can be supplied in 200L drums or 1,000L IBC’s. The IBC installation can involve fibreglass IBC bunds which store chemical in a safe manner and make chemical handling and changeover easy without operator involvement.
|
|
Turnkey System Dioxide Pacific offers turnkey systems including all aspects of design, installation and commissioning. Why try and put the system together yourself? Our quality project management system ensures the plant will be installed on time, at low risk with the smallest possible interruption to your site. We have proven risk management protocols written specifically for chlorine dioxide systems to ensure that installation, commissioning, training and operation of the plant is extremely safe.
Chlorine dioxide systems can be installed in dedicated plant rooms, skids for transportation to remote sites or in portable buildings.
|
|
|
|
Typical Applications The use of chlorine dioxide is limitless. However, some widely used applications include the following:
- Milk powder condensate disinfection for re-use
- Potable water disinfection
- Waste water disinfection
- Nursery irrigation water disinfection for disinfestation of plant pathogens
- Vegetable and fruit washing
- Beverage industry process water disinfection
- Food industry process water disinfection
- Membrane (RO, NF, UF) sanitisation
- CIP sanitisation
- Iron and manganese oxidation
- Cooling tower disinfection for Legionalla destruction
- Cooling system macro and micro fouling control for fresh water and sea water circuits
- Poultry processing chiller water disinfection
Please see our Systems page for more information on chlorine dioxide systems we have provided.
|
|
Generator Capacities
- HP-100 100 ppd 1,894 g/hr
|
Brochure Downloads
|
|
|
For more information on chlorine dioxide systems or to arrange a site visit or quotation, please complete the feedback sheet
|